Full question: In these statistics (100% of all datasets have issues), was Solargis involved in the project on the ground, i.e. did you know the exact topography of the installation, or how the sensor tilt really was in real life? Often the theoretical tilt of PV modules from a CAD file or design is not consistent with what is installed on the ground, so many pyranometer values are flagged as faulty, when in fact they are perfectly aligned with the PV modules. So you can't just throw away these data as false due to theoretical considerations or clear sky models.
Answer: Thank you, we fully agree that the as-built geometry often differs from the design, and that this must be respected in QC.
Two clarifications to the statistic:
1) "100% of datasets have issues" means that every dataset had at least one QC finding of any type – e.g. values below/above physical limits, shading, dew/frost, soiling, static (stuck) values, timestamp shifts, logger outages, misalignment. A single occurrence was enough. It does not mean that the datasets were unusable or that large parts of them were removed.
2) Solargis is not involved in field quality checks, so we have no independent knowledge of the as-built geometry. We can only rely on the documentation provided to us. The customer is therefore responsible for providing a verified configuration of the PV system and of the solar instruments (sensor tilt and azimuth, tracker configuration, horizon, site photos, maintenance logs).
We take these documents as the ground truth and carry out automatic and manual (expert) tests. These tests reveal issues both in the measured data and in the provided meteo station and PV configuration.
Misalignment is flagged when the data show the typical signature (e.g. systematic morning/afternoon asymmetry on clear-sky days, consistent with other sensors and the model) and the deviation from the declared configuration exceeds a threshold.
If a pyranometer is aligned with the as-built modules and this geometry is declared, its data pass. If the declared metadata are wrong (e.g. sensor declared horizontal but installed tilted), the flag is correct with respect to the declaration.
In such a case, the finding points to an error in the provided configuration rather than in the sensor. We then clarify the as-built geometry with the customer and re-evaluate the data.