As PV power grows in the global energy mix, forecast accuracy has never mattered more. Reliable GHI and PVOUT predictions help grid operators maintain stability, asset owners avoid penalties, and traders optimize their strategies.

验证研究详情#

这项验证研究通过将预测值与卫星数据进行比较,评估了太阳能和 PVOUT 预测的准确性。

  • 地点153 个全球站点,遍布各大洲
  • 范围: 提前一小时(现在预报)和提前一天
  • 结果按主要气候区分组:温带、寒带、干旱、热带和极地
  • 指标:偏差、平均绝对偏差 (MAD) 和均方根偏差 (RMSD)

本验证研究中的 PVOUT 精度统计基于以下配置:

  • 几何形状:固定(一个角度)
  • 方位角(方向):0°或 180°,视半球而定
  • 倾斜度特定位置的最佳角度
  • 安装容量: 10,000 千瓦
  • 光伏组件技术: CSICSI

详细的光伏配置参数可参见此处 ->

GHI represents the total solar irradiance incident on a horizontal surface and is the primary meteorological driver of PV power output. Validating GHI forecast accuracy is therefore a critical first step in assessing the overall quality of the forecasting system.

See the numbers behind Solargis GHI forecasts. Hour-ahead and day-ahead accuracy validated across 153 global sites in all major climate zones.

GHI 验证统计

Hour-ahead (nowcast) accuracy

What we did

  • Generated hour-ahead GHI forecasts using Solargis's internal Cloud Motion Vector (CMV) model, which tracks cloud movement from satellite imagery.
  • Validated forecasts against satellite-based reference GHI for 153 globally distributed sites, covering all major climate zones.
  • Compared accuracy at hourly and 15-minute temporal resolutions using data from 2025.
  • Calculated Bias, MAD, and RMSD as standard accuracy indicators, both globally and per climate zone.

Results we obtained

GHI Hourly 15-min
Average Bias -0.18% -0.18%
Average MAD 4.87% 5.39%
Average RMSD 8.58% 9.58%

Full results by climate zone ->

Conclusions

  • Forecast accuracy is better for hourly than for 15-minute data, primarily due to temporal aggregation effects that smooth short-term variability.
  • Arid regions achieve the best performance due to stable, clear-sky conditions.
  • Temperate and cold climates show moderate errors driven by variable cloud cover and frontal systems.
  • Tropical and polar regions exhibit the highest errors, caused by convective activity, rapid cloud formation, low sun angles, and seasonal extremes.

Day-ahead accuracy

What we did

  • Generated day-ahead GHI forecasts (approximately 24–48 hours ahead) using Numerical Weather Prediction (NWP) models.
  • Validated the same 153 global sites at hourly and 15-minute resolutions using 2025 data.
  • Compared results with hour-ahead accuracy to quantify the effect of extended forecast horizon on accuracy.

Results we obtained

GHI Hourly 15-min
Average Bias 0.56% 0.57%
Average MAD 6.15% 6.61%
Average RMSD 10.11% 10.89%

Full results by climate zone ->

Conclusions

  • Accuracy is lower compared to hour-ahead forecasts due to the longer prediction horizon.
  • Arid regions achieve the best performance due to stable conditions.
  • Tropical regions perform worst due to convective cloud formation.
  • Polar regions show lower accuracy, partly influenced by limited sample size.
  • Temperate and cold climates show moderate errors.

PVOUT is the electrical power produced by a PV system when sunlight is converted into electricity by PV modules. GHI is the primary input for PVOUT, but accuracy also depends on PV system configuration parameters such as module tilt and orientation, installed capacity, shading conditions, and system losses.

See the numbers behind Solargis PVOUT forecasts. Hour-ahead and day-ahead accuracy validated across 153 global sites in all major climate zones.

PVOUT 验证统计

Hour-ahead (nowcast) accuracy

What we did

  • Transformed hour-ahead GHI forecasts into PVOUT forecasts using the same fixed PV system configuration.
  • Validated accuracy for all 153 sites, comparing with hour-ahead results to quantify the horizon effect.
  • Calculated Bias, MAD, and RMSD both globally and per climate zone, at hourly and 15-minute resolution.
  • Additionally analyzed minimum and maximum MAD across sites to quantify variability in forecast performance.

Results we obtained

PVOUT Hourly 15-min
Average Bias -0.15% -0.15%
Average MAD 4.89% 5.40%
Average RMSD 8.66% 9.68%

Full results by climate zone ->

Conclusions

  • Overall PVOUT and GHI accuracy patterns are very similar, as GHI is the primary input to PVOUT.
  • Bias is close to zero across all climate zones, but average bias alone does not reflect full forecast quality — MAD is the most important indicator as it captures the typical magnitude of deviations regardless of direction.
  • Best hour-ahead PVOUT accuracy is achieved in arid zones and worst in polar and tropical zones.

Day-ahead accuracy

What we did

  • Transformed day-ahead GHI forecasts into PVOUT forecasts using the same fixed PV system configuration.
  • Validated accuracy for all 153 sites, comparing with hour-ahead results to quantify the horizon effect.
  • Analyzed MAD min/max variability across sites to support realistic accuracy expectations for operational use.

Results we obtained

PVOUT Hourly 15-min
Average Bias 1.08% 1.08%
Average MAD 6.27% 6.70%
Average RMSD 10.49% 11.24%

Full results by climate zone ->

Conclusions

  • Day-ahead PVOUT accuracy is slightly worse than hour-ahead.
  • The day-ahead horizon is the most critical for electricity market participation, grid planning, and battery storage optimization.
  • Forecast accuracy can differ significantly by site — both the average MAD and the variability expressed by minimum and maximum values should be considered when evaluating expected performance.